Stock code:SZ 002334
Close
Product Inquiry
  • *Name:
  • Company:
  • *Country:
  • *E-mail Address:
  • Phone:
  • *Content:
Current location:Home  Products  Industrial Automation  Controller  PLC
PLC
IVC2 Programmable Controller
  • IVC2 Programmable Controller
  • IVC2 Programmable Controller
  • IVC2 Programmable Controller
  • IVC2 Programmable Controller
  • IVC2 Programmable Controller
IVC2 Programmable Controller

IVC2 series small multi-functional application PLC boasts powerful communication capacity, strong system extension capacity and stable and reliable performance.

Inquiry
  • Features
  • Specification parameter
  • Classic case
  • Data download
  • 1. Max I/O points can reach up to 512 points;

    2. Support up to 8 special function extension modules;

    3. Can extend RS485 communication port and CANOpen communication port.

     

  • Name

    IVC2L

    I/O

    Digital I/O point

    20 inputs/12 outputs

    32 inputs/32 outputs

    Logic max I/O point

    512

    Max special module number

    8

    Highs peed pulse output

    IVC2L2×100kHz (only suitable for transistor output type)

    1PH counting channel

    IVC2L2×50kHz4×10kHz

    2PH counting channel

    IVC2L1×30kHz1×5kHz

    Max value of the total sum of high speed counter frequency 

    IVC2L80kHz

    Digital filter function

    X0X17 adopt digital filter, input filter constant range: 060ms

    Max relay output current

    Resistor load

    2A/1点;8A/4 point group command terminal8A/8 point group common terminal

    Inductive load

    220Vac, 80VA

    Light load

    220Vac, 100W

    Max current of transistor outptu point

    Resistor load

    High speed output point0.3A/1 pointothers0.3A/1 point0.8A/4 points1.6A/8points

    The total current increases by 0.1A for eevery additional 1 point above 8points.

    Inductive load

    High speed output point7.2W/24Vdcothers12W/24Vdc

    Light load

    High speed output point0.9W/24Vdcothers1.5W/24Vdc

    Storage

    User program

    12k tep (24kByte)

    Permannet maintenance after power off

    Yes

    Max number of component maintained at power off

    Set by user (for C compoennt, the max number is 200)

    Hardware support and maintenance time

    Backup battery, maintain for three years

    Soft component resource

    Timer

    100ms precisionT0T209  

    10ms precisionT210T251

    1ms precisionT252T255

    Counter

    16-bit up counterC0C199

    32-bit up down counterC200C235

    32-bit high speed counterC236C255

    Data register

    D0D7999

    Local data register

    V0V63

    Indexed addressing register

    Z0Z15

    Special data register

    SD0SD255

    Auxiliary relay

    M0M1999

    Local auxiliary relay

    LM0LM63

    Special auxiliary relay

    SM0SM255

    State relay

    S0 S991

    Interruption resources

    Internal timing interruption

    3

    External interruption

    16

    High speed counter interruption

    6

    Serial interruption

    12

    PTO output completion interruption

    2

    Power loss interruption

    1

    Regular

    Basic command running time

    0.09μS

    Real-time clock

    Support

    Analog potentiomenter

    2/8-bit precision

    Communication

    Communication port

    PORT0RS232

    PORT1RS232/RS485

    Communication protocol

    Modbus/free port N:N/program port protocol

    Encryption measure

    Set password type

    Upload password, download password, monitor password, sub-program password, formatting prohibited

    Upload prohibited

    Support

    Application command

    Real-time clock, clock command

    Yes

    Date and clock comparison command

    Yes

    Floating point number command

    Yes

    Positioning command

    Yes

    High speed IO command

    Yes

    MODBUS and inverter command

    Yes

    EEPROM RW command

    Yes

    Control computation command

    Yes

    Character string command

    No

    Bulk data processing command

    No

    Data sheet command

    No

    MTBF

    Relay output

    200,000H (fixed to ground, mechanical stress closed to zero, with temp and RH control)

    100,000H (fixed to ground, mechanical stress closes to zero, without temp and RH control)

    Transistor output

    300,000H (fixed to ground, mechanical stress closes to zero, with temp and RH control)

    150,000H (mechanical stress closes to zero, without temp and RH control)

    Servicelife of outputrelay contact

    220Vac/15VA/inductive

    1sON/1s OFF, 3,200,000 times

    220Vac/30VA/inductive

    1s ON/1s OFF, 1,200,000 times

    220Vac/72VA/inductive

    1s ON/1s OFF, 300,000 times

    Ambient environment

    Rated voltage

    100240VAC (normal operation)

    Input voltage range

    85264VAC (normal operation)

    Ambient temp

    -555

    Storage temp

    -4070

    Withstand voltage

    1 minute of 2830VAC AC or equivalent DC voltage, no breakdown or arching, leakge current 5mA

    Withstand vibration

    Displacement3.5mm, acceleration10m/s2, frequency range5150Hz, scan 10 times in X, Y and Z direction

    Withstand shock

    Half sine, pulse width6ms, acceleration180m/s2

    Protection level

    IP20

    Safety certification

    Design according to IEC61131-2 and UL508 standard, pass CE certification