IVC2 series small multi-functional application PLC boasts powerful communication capacity, strong system extension capacity and stable and reliable performance.
1. Max I/O points can reach up to 512 points;
2. Support up to 8 special function extension modules;
3. Can extend RS485 communication port and CANOpen communication port.
Name |
IVC2L |
||
I/O |
Digital I/O point |
20 inputs/12 outputs 32 inputs/32 outputs |
|
Logic max I/O point |
512 |
||
Max special module number |
8 |
||
Highs peed pulse output |
IVC2L:2×100kHz (only suitable for transistor output type) |
||
1PH counting channel |
IVC2L:2×50kHz+4×10kHz |
||
2PH counting channel |
IVC2L:1×30kHz+1×5kHz |
||
Max value of the total sum of high speed counter frequency |
IVC2L:80kHz |
||
Digital filter function |
X0~X17 adopt digital filter, input filter constant range: 0~60ms |
||
Max relay output current |
Resistor load |
2A/1点;8A/4 point group command terminal;8A/8 point group common terminal |
|
Inductive load |
220Vac, 80VA |
||
Light load |
220Vac, 100W |
||
Max current of transistor outptu point |
Resistor load |
High speed output point:0.3A/1 point;others:0.3A/1 point;0.8A/4 points;1.6A/8points The total current increases by 0.1A for eevery additional 1 point above 8points. |
|
Inductive load |
High speed output point:7.2W/24Vdc;others:12W/24Vdc |
||
Light load |
High speed output point:0.9W/24Vdc;others:1.5W/24Vdc |
||
Storage |
User program |
12k tep (24kByte) |
|
Permannet maintenance after power off |
Yes |
||
Max number of component maintained at power off |
Set by user (for C compoennt, the max number is 200) |
||
Hardware support and maintenance time |
Backup battery, maintain for three years |
||
Soft component resource |
Timer |
100ms precision:T0~T209 10ms precision:T210~T251 1ms precision:T252~T255 |
|
Counter |
16-bit up counter:C0~C199 32-bit up down counter:C200~C235 32-bit high speed counter:C236~C255 |
||
Data register |
D0~D7999 |
||
Local data register |
V0~V63 |
||
Indexed addressing register |
Z0~Z15 |
||
Special data register |
SD0~SD255 |
||
Auxiliary relay |
M0~M1999 |
||
Local auxiliary relay |
LM0~LM63 |
||
Special auxiliary relay |
SM0~SM255 |
||
State relay |
S0~ S991 |
||
Interruption resources |
Internal timing interruption |
3 |
|
External interruption |
16 |
||
High speed counter interruption |
6 |
||
Serial interruption |
12 |
||
PTO output completion interruption |
2 |
||
Power loss interruption |
1 |
||
Regular |
Basic command running time |
0.09μS |
|
Real-time clock |
Support |
||
Analog potentiomenter |
2/8-bit precision |
||
Communication |
Communication port |
PORT0:RS232 PORT1:RS232/RS485 |
|
Communication protocol |
Modbus/free port N:N/program port protocol |
||
Encryption measure |
Set password type |
Upload password, download password, monitor password, sub-program password, formatting prohibited |
|
Upload prohibited |
Support |
||
Application command |
Real-time clock, clock command |
Yes |
|
Date and clock comparison command |
Yes |
||
Floating point number command |
Yes |
||
Positioning command |
Yes |
||
High speed IO command |
Yes |
||
MODBUS and inverter command |
Yes |
||
EEPROM RW command |
Yes |
||
Control computation command |
Yes |
||
Character string command |
No |
||
Bulk data processing command |
No |
||
Data sheet command |
No |
||
MTBF |
Relay output |
200,000H (fixed to ground, mechanical stress closed to zero, with temp and RH control) |
|
100,000H (fixed to ground, mechanical stress closes to zero, without temp and RH control) |
|||
Transistor output |
300,000H (fixed to ground, mechanical stress closes to zero, with temp and RH control) |
||
150,000H (mechanical stress closes to zero, without temp and RH control) |
|||
Servicelife of outputrelay contact |
220Vac/15VA/inductive |
1sON/1s OFF, 3,200,000 times |
|
220Vac/30VA/inductive |
1s ON/1s OFF, 1,200,000 times |
||
220Vac/72VA/inductive |
1s ON/1s OFF, 300,000 times |
||
Ambient environment |
Rated voltage |
100~240VAC (normal operation) |
|
Input voltage range |
85~264VAC (normal operation) |
||
Ambient temp |
-5~55℃ |
||
Storage temp |
-40~70℃ |
||
Withstand voltage |
1 minute of 2830VAC AC or equivalent DC voltage, no breakdown or arching, leakge current ≤5mA |
||
Withstand vibration |
Displacement:3.5mm, acceleration:10m/s2, frequency range:5~150Hz, scan 10 times in X, Y and Z direction |
||
Withstand shock |
Half sine, pulse width:6ms, acceleration:180m/s2 |
||
Protection level |
IP20 |
||
Safety certification |
Design according to IEC61131-2 and UL508 standard, pass CE certification |