BN 1-6kW Off-grid

iMars BN series single-phase photovoltaic off grid inverter combines the traditional off-grid uninterrupted power function with solar power generation control technologies, providing flexible and reliable system solutions for households and industry purposes.

Inquiry
  • Features
  • Specification parameter
  • Classic case
  • Data download
  • 1.Efficient

    It has many kinds of battery charging voltage, and uses many kinds of energy storage battery to make the battery maximized;

    A variety of modes of work for use, such as city power priority, battery priority, energy saving mode, etc., to provide load energy;

    City Electric bypass quick charge;

    Charge control function with photovoltaic panel MPPT (maximum power tracking);

    2.Reliable

    It has overload, short circuit and other protection functions;

    It can continuously provide energy for linear and nonlinear loads, such as electric lamps, computers, refrigerators, air conditioners, fans and other household appliances and industrial power;

    Products liability insurance and errors or omissions liability insurance are covered by the international famous property insurance company AIG insurance;

    3. Intelligence

    Provide a variety of user-friendly communication module selection, such as RS485, RS232, CAN, DPRS, WiFi and so on, suitable for computers, mobile phones, or Internet monitoring and remote operation.

  •  

    BN1024C

    BN1524C

    BN2024C

    BN3024C

    BN4048C

    BN5048C

    BN6048C

    Mains model specification

    Rated input voltage (V)

    220/230

    Rated output voltage range (V)

    155~272 (±2%)

    Rated frequency (Hz)

    50HZ/ 60HZ (First automatic detection )

    Frequency range (Hz)

    47+0.3Hz ~ 55+0.3Hz for 50Hz;  ( 57+0.3Hz ~ 65+0.3Hz for 60Hz)

    Overload/short circuit protection

    Circuit breaker

    Efficiency

    >95%

    Conversion time (ms)

    10ms (Typical values)

    (AC transfer DC or DC to AC)

    Current specification of bypass relay (A)

    30

    40

    Specification of contravariant mode

    Voltage output waveform

    Sine wave

    Rated output (VA)/(W)

    1000/1000

    1500/1500

    2000/2000

    3000/3000

    4000/4000

    5000/5000

    6000/6000

    Power factor

    1

    Rated output voltage (V)

    230

    220/230/240

    Output voltage error range

    ±10%

    Rated output frequency (Hz)

    50Hz ±0.3Hz/60Hz ± 0.3Hz

    Efficiency

    >85%

    Overload protection

    (110% "load <125%) plus or minus 10%: load off after 15 minutes;

    (125%< load <150%) plus or minus 10%: load off after 60 seconds.

    Load >150% plus or minus 10%: power off after 20 seconds overload

    Peak power (10 seconds) (VA)

    3000

    4500

    6000

    11000

    12000

    15000

    18000

    Motor/air conditioning capacity (piece)

    1

    2

    3

    4

    5

    Output short circuit protection

    Current limit (short circuit 10 seconds after shutdown)

    Output circuit breaker current specification (A)

    10

    30

    40

    Dc input voltage (V)

    24/22

    48/ 24

    Minimum dc starting voltage (V)

    DC input voltage range (V)

    20.0~ 32, + 0.6Vdc deviation (low voltage alarm: 21V; Shutdown: 20V; High voltage fault: 32V; High voltage recovery: 31V)

    40.0~ 64, + 0.6Vdc deviation (low voltage alarm: 42V; Shutdown: 40V; High voltage failure: 64V; High voltage recovery: 62V)

    Main working mode

    0-6 market power priority, 7-9 battery priority

    AC input charging specifications

    Charging current (A)

    20

    25

    35

    50

    35

    40

    50

    Charging current deviation (A)

    ± 5

    Battery voltage range (V)

    20 –31.4

    40 –62.8

    Charging short circuit protection

    Circuit breaker

    Charging circuit breaker specification (A)

    10

    30

    The overcharge protection

    The battery voltage is greater than 31.4 V, and the charging is closed every second and after 60 seconds

    The battery voltage is greater than 62.8 V, and the charging is closed every second and after 60 seconds

    Solar charging specifications

    MPPT operating voltage range (V)

    18-78

    64-145

    Maximum PV dc input voltage (V)

    100

    145

    Maximum PV open circuit voltage (V)

    78

    145

    Rated charging current (A)

    45

    60

    Maximum load charging efficiency

    98%

    Battery short circuit protection

    The fuse

    Solar panel connection protection

    Anti-collision protection

    Other specifications

    Dimensions (H x W x D mm)

    410 x 264 x 180

    460 x 264 x 180

    555 x 264 x 180

    Weight (kg)

    16

    19

    22

    26

    31

    34

    36

    To protect grade

    IP20Forced air cooling, fan speed adjustable

    Working temperature

    -15°C to 40°C  (-25ºC 60ºC Storage temperature)

    Working humidity

    5% to 95%

    Noise (dB)

    60

    Communication interface

    RS-485/ GPRS/WiFi/remote control

    Safety Certification/EMC rating

    CE(EN62040-1, EN62040-2/ C2

    Warranty (year)

    1 year

    • No Record
    • Name Editionformat format Size Date download
    • No Record
Related products recommended
Email: overseas@invt.com.cn
Learn more about latest solutions and cases, please enter your email address to subscribe to
Online top

Our site uses cookies to provide you with a better onsite experience. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Cookie Policy .